MITSUBISHI CNC
#13193 SP193 LMR Change magnification for load meter standard output (High-speed
coil)
Set the standard output to be displayed as 100% in load meter using the short-time rated output
ratio.
To display the continuous rated output as 100%, set as follows.
Continuous rated output/Short-time rated output × 100
When "0" is set, normal display will be applied.
It is not available for MDS-D-SPJ3 Series.
---Setting range---
0 to 100 (%)
#13194 SP194 LMN Base speed for load meter standard output (High-speed coil)
Set the base speed of the standard output to be displayed as 100% in load meter.
When "0" is set, the base speed of the short-time rated output will be applied.
It is not available for MDS-D-SPJ3 Series.
---Setting range---
0 to 32767 (r/min)
#13195 SP195 LMRL Change magnification for load meter standard output (Low-speed
coil)
Set the standard output to be displayed as 100% in load meter using the short-time rated output
ratio.
To display the continuous rated output as 100%, set as follows.
Continuous rated output/Short-time rated output × 100
When "0" is set, normal display will be applied.
It is not available for MDS-D-SPJ3 Series.
---Setting range---
0 to 100 (%)
#13196 SP196 LMNL Base speed for load meter standard output (Low-speed coil)
Set the base speed of the standard output to be displayed as 100% in load meter.
When "0" is set, the base speed of the short-time rated output will be applied.
It is not available for MDS-D-SPJ3 Series.
---Setting range---
0 to 32767 (r/min)
#13197 SP197
Not used. Set to "0".
#13198 SP198
Not used. Set to "0".
#13199 SP199
Not used. Set to "0".
#13200 SP200
Not used. Set to "0".
#13201 SP201
Not used. Set to "0".
#13202 SP202
Not used. Set to "0".
#13203 SP203
Not used. Set to "0".