MDS-D-SVJ3/SPJ3 Series Instruction Manual
2-2 Main circuit terminal block/control circuit connector
2 - 11
2-2-3 Main circuit connector (CNP1,CNP2,CNP3) wiring method
Use the supplied drive unit power supply connectors for wiring of CNP1, CNP2 and CNP3.
(1) MDS-D-SVJ3-03NA/04NA/07NA
, MDS-D-SPJ3-075NA
(a) Drive unit power supply connectors
(b) Termination of the cables
Solid wire: After the sheath has been stripped, the cable can be used as it is.
Twisted wire: Use the cable after stripping the sheath and not twisting the core. At this time, take
care to avoid a short caused by the loose wires of the core and the adjacent pole.
Do not solder the core as it may cause a contact fault. Alternatively, a bar terminal
may be used to put the wires together.
For the wire size used for wring, refer to the section "5-1 selection of wire" in MDS-D-SVJ3/SPJ3
Series Specifications Manual.
MDS-D-SPJ3-55NA/75NA/110NA does not have these connectors.
Cable size Bar terminal type
Crimping tool Manufacturer
[mm
2
]
AWG For 1 cable For 2 cables
1.25 16
BT1.25-9-1 - NH1 NICHIFU
TUB-1.25 - YHT-2210 Japan Solderless Terminal
1.5 16 AI1.5-8BK
AI-TWIN2×1.5-8BK
CRIMPFOX-UD6 Phoenix Contact
AI-TWIN2×1.5-12BK
214
BT2-9-1 - NH1 NICHIFU
TUB-2 - YHT-2210 Japan Solderless Terminal
POINT
CNP2
CNP1
CNP3
549280610(Molex)
549270510(Molex)
549280310(Molex)
Ǿ
8 to 9mm
Core
Sheath