Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
Appendix 2 - 10
Appendix 2 Cable and Connector Assembly
MITSUBISHI CNC
Appendix 2-2 CM10-APxxS-x(D6) angle plug connector
This section explains how to assemble the wire to CM10 angle plug connector.
(1) Cutting a cable
Cut the cable to the following dimensions:
Cable length after cutting = measurement A for CM10-APxxS-x(D6)+ Cable length
= A + Cable length
(2) Stripping a cable sheath
Strip the cable sheath to the length A as shown below.
(Note) Take care the cable peel length.
Take care not to damage anything.
* When making CM10-AP10S-x(D6), strip the cable for No. 10 terminal in a way that makes the
A length 1mm longer than other cables.
(To avoid the cable tension when inserting a contact to the housing in a later process.)
Product name A [mm]
CM10-APxxS-S(D6)
40±0.5
CM10-APxxS-M(D6)
CM10-APxxS-L(D6) 55±0.5
Product name A [mm]
CM10-APxxS-S(D6)
30±0.5
CM10-APxxS-M(D6)
CM10-APxxS-L(D6) 45±0.5
Cable length
A
Sheath
Core wire
(A+1mm for No. 10 terminal only)