Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
4 - 5
MDS-D-SVJ3/SPJ3 Series Instruction Manual
4-1 D/A output specifications for servo drive unit
4-1-3 Setting the output magnification
Set when outputting other than the standard output unit. When "0" is set, the magnification will be the same
as "100".
(Example 1) When SV061=1 and SV063=50
The motor rotation speed is output at 2000(r/min)/V.
(Example 2) When SV062=3 and SV064=50
The torque feedback is output to D/A output channel 2 with 200%/V unit.
#2263 SV063 DA1MPY D/A output ch1 output scale
Set output scale of the D/A output channel 1 in increment of 1/100.
When "0" is set, the magnification is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)
#2264 SV064 DA2MPY D/A output ch 2 output scale
Set output scale of the D/A output channel 2 in accruement of 1/100.
When "0" is set, the magnification is the same as when "100" is set.
---Setting range---
-32768 to 32767 (1/100-fold)