3-3 Setting the initial parameters for the spindle drive unit
【#13086】 SP086 LMCc Lost motion compensation 3 viscous coefficient
Set the compensation amount for the viscous coefficient when using lost motion compensation type
3.
When not using, set to "0".
---Setting range---
0 to 32767 (0.01% - s/ 1°)
【#13087】 SP087 FHz4 Notch filter frequency 4
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
---Setting range---
0 to 2250 (Hz)
【#13088】 SP088 FHz5 Notch filter frequency 5
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
---Setting range---
0 to 2250 (Hz)
【#13089】 SP089 TMKQ Spindle output stabilizing gain Q axis
Set the magnification of the torque current stabilizing gain. (For machine tool builder adjustment)
When set to "0", the torque current stabilization is disabled.
When not using, set to "0".
---Setting range---
0 to 32767
【#13090】 SP090 TMKD Spindle output stabilizing gain D axis
Set the magnification of the excitation current stabilizing gain. (For machine tool builder adjustment)
When set to "0", the excitation current stabilization is disabled.
When not using, set to "0".
---Setting range---
0 to 32767
【#13091】 SP091
Not used. Set to "0".
【#13092】 SP092
Not used. Set to "0".
【#13093】 SP093
Not used. Set to "0".