Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
5 - 38
5 Spindle Adjustment
MITSUBISHI CNC
5-3 Settings for emergency stop
Emergency stop in this section refers to the following states.
[1] Emergency stop was input (including other axis alarms)
[2] NC power down was detected
[3] A drive unit alarm was detected
5-3-1 Deceleration control
With the MDS-D-SPJ3 spindle drive unit, the motor will decelerate following the time constant set at
emergency stop. When the CNC confirms the zero speed of all axes, contactor of the spindle drive unit is
turned OFF.
(1) Setting the deceleration control time constant
Set the time for stopping from the maximum motor speed (TSP) in the deceleration time constant for
emergency stop (SV056: EMGt). When "0" is set, the deceleration stop is executed with "7000ms".
<Operation>
When an emergency stop occurs, the motor will decelerate at the same inclination from each speed.
(Note) If the setting value of SP056 is longer than the value of SP055, the motor will coast.
#13055 SP055 EMGx Max. gate off delay time after emergency stop
Set the time required to forcibly execute READY OFF after the emergency stop is input.
Normally set to "20000".
When "0" is set, READY OFF is forcibly executed with "7000ms".
When the set time is shorter than the time to decelerate and stop, the spindle will stop with the
dynamic brake after the set time is out.
---Setting range---
0 to 29900 (ms)
#13056 SP056 EMGt Deceleration time constant at emergency stop
Set the time constant used for the deceleration control at emergency stop. Set the time required to
stop from the maximum motor speed (TSP).
When "0" is set, the deceleration control is executed with "7000ms".
---Setting range---
-29900 to 29900 (ms)
TSP
056
055
(EMG)
(ZSP)
(READY)
Forced READY OFF range
Constant
inclination
deceleration
Motor s
p
eed
Time
Deceleration control sequence
Emergency stop
Servo READY
Zero speed