Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 56
3 Setup
MITSUBISHI CNC
#13064(PR) SP064 GRB4 Motor side gear ratio 4
Set the number of teeth on the spindle side when "the gear selection command (control input 4/bit6,
5)" is set to "11".
---Setting range---
1 to 32767
< Setting parameters for the detector with semi/full-closed loop control >
Set parameters depending on the detector configured in the machine. For semi-closed loop, set the same
value to the main side and the sub side. For full-closed loop, set the detector of the main side and the sub
side.
#13019(PR) SP019 RNG1 Sub side detector resolution
[For semi-closed loop]
Set the same value as SP020 (RNG2). (Refer to the explanation of SP020.)
[For full-closed loop]
Set the number of pulses per revolution of the speed detector.
When using ABZ pulse encoder, used this with SP097(RNG1ex).
E.g.: The setting for ABZ pulse encoder "OSE-1024-3-15-68"
SP019 = 4096
SP097 = -1
---Setting range---
-32768 to 32767 (kp/rev)
When using SP097: (p/rev)
#13020(PR) SP020 RNG2 Main side detector resolution
Set the number of pulses per revolution of the main side detector.
When using the serial changer MDS-B-HR, use this with SP098(RNG2ex).
Detector
TS5691(128 teeth): SP020 = 2000
TS5691(180 teeth): SP020 = 2880
TS5691(256 teeth): SP020 = 4000
TS5691(384 teeth): SP020 = 6000
TS5691(512 teeth): SP020 = 8000
TS5690( 64 teeth): SP020 = 2000
TS5690( 90 teeth): SP020 = 2880
TS5690(128 teeth): SP020 = 4000
TS5690(192 teeth): SP020 = 6000
TS5690(256 teeth): SP020 = 8000
TS5690(384 teeth): SP020 =12000
ERM280(1200 teeth): SP020 = 4800
ERM280(2048 teeth): SP020 = 8000
MPCI : SP020 = 7200
MBE205: SP020 = 2000
OSA18(-A48): SP020 = 260
---Setting range---
-32768 to 32767 (kp/rev)
When using SP098: (p/rev)