Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 87
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-3 Setting the initial parameters for the spindle drive unit
#3044 tapt24 Synchronous tap switching time constant 2 (Gear: 11)
Set the time constant to reach synchronous tapping switching spindle rotation speed 2 (taps21 - 24)
with gear 11.
---Setting range---
1 to 5000 (ms)
#3045 tapt31 Synchronous tap switching time constant 3 (Gear: 00)
Set the time constant to reach the maximum speed (smax1 - 4) with gear 00.
---Setting range---
1 to 5000 (ms)
#3046 tapt32 Synchronous tap switching time constant 3 (Gear: 01)
Set the time constant to reach the maximum speed (smax1 - 4) with gear 01.
---Setting range---
1 to 5000 (ms)
#3047 tapt33 Synchronous tap switching time constant 3 (Gear: 10)
Set the time constant to reach the maximum speed (smax1 - 4) with gear 10.
---Setting range---
1 to 5000 (ms)
#3048 tapt34 Synchronous tap switching time constant 3 (Gear: 11)
Set the time constant to reach the maximum speed (smax1 - 4) with gear 11.
---Setting range---
1 to 5000 (ms)
#3049 spt Spindle synchronization acceleration/deceleration time constant
Set the acceleration/deceleration time constant for when the commanded spindle synchronization
speed changes under spindle synchronization control.
---Setting range---
0 to 9999 (ms)
#3050 sprlv Spindle synchronization rotation speed attainment level
Set the level of difference between the commanded synchronization spindle speeds and actual
speeds of both the basic and synchronous spindles during spindle synchronization, below which the
spindle speed synchronization complete signal will go ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)
#3051 spplv Spindle phase synchronization attainment level
Set the level of phase difference between the basic and synchronous spindles during spindle
synchronization, below which the spindle phase synchronization complete signal will go ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)