3 - 43
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-2 Setting the initial parameters for the servo drive unit
【#2294】 SV094 MPV Magnetic pole position error detection speed
The magnetic pole position detection function monitors the command speed and motor speed at the
position command stop and detects the magnetic pole position error alarm (3E) if any. Set the error
detection level for the command speed and motor speed at the position command stop.
Be aware when setting the parameter as the setting units for general motors and linear motors are
different.
<<For general motor>>
When the command speed error detection level is set to "0", the magnetic pole position error (3E) is
detected at 10r/min.
Set "10" as standard.
This detects the magnetic pole position error (3E) when the motor rotation speed is 100r/min and
more.
<<For linear motor>>
When the command motor speed level is set to "0", the magnetic pole position error (3E) is detected
at 1mm/s.
Set "10" as standard.
This detects the magnetic pole position error (3E) when the motor speed is 10mm/s and more.
---Setting range---
0 to 31999
<<For general motor>>
Ten-thousands digit, Thousands digit ----------- Command speed error detection level (10r/min)
Hundreds digit, Tens digit, Ones digit ----------- Motor speed error detection level (10r/min)
<<For linear motor>>
Ten-thousands digit, Thousands digit ----------- Command speed error detection speed level
(10r/min)
Hundreds digit, Tens digit, Ones digit ----------- Motor speed error detection level (10r/min)
【#2295】 SV095 ZUPD Vertical axis pull up distance
Set this parameter to adjust the pull up distance when the vertical axis pull up function is enabled.
When the pull up function is enabled and this parameter is set to "0", for a rotary motor, 8/1000 of a
rotation at the motor end is internally set as the pull up distance, and for a linear motor, 80[μm] is set.
Related parameters:
SV032 : The pull up direction is determined. When "0" is set, pull up control is not executed.
SV033/bitE : Start-up of the pull up function
SV048 : Set the drop prevention time. When "0" is set, pull up control is not executed.
---Setting range---
0 to 2000 (μm)
【#2296】 SV096
Not used. Set to "0".
【#2297】 SV097
Not used. Set to "0".
【#2298】 SV098
Not used. Set to "0".
【#2299】 SV099
Not used. Set to "0".
【#2300】 SV100
Not used. Set to "0".
【#2301】 SV101
Not used. Set to "0".