Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 107
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-3 Setting the initial parameters for the spindle drive unit
#13033 SP033 SFNC1 Spindle function 1
Select the spindle specification.
A function is allocated to each bit.
Set this in hexadecimal format.
bit F-C :
Not used. Set to "0".
bit B-A : ovs Overshoot compensation
bitB,A=
00: Compensation stop
01: Setting prohibited
10: Setting prohibited
11: Compensation type 3
(Note) Set the compensation amount in SP043(OVS1) and SP042(OVS2).
bit 9-8 : lmc Lost motion compensation
bit9,8=
00: Compensation stop
01: Setting prohibited
10: Compensation type 2
11: Setting prohibited
(Note) Set the compensation amount in SP048(LMC1) and SP041(LMC2).
When "SP227/lmc3" is set to "1", the lost motion compensation type 3 is selected regardless of this
setting.
bit 7 : lmc2a Lost motion compensation 2 timing
0: Normal timing 1: Timing changed
bit 6 :
Not used. Set to "0".
bit 5-4 :
Not used. Set to "0".
bit 3-2 :
Not used. Set to "0".
bit 1-0 : vcnt Delay compensation changeover
bit1,0=
00: Disable
01: Changeover type 1
10: Changeover type 2
11: Changeover type 2