Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 101
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-3 Setting the initial parameters for the spindle drive unit
#13017(PR) SP017 SPEC1 Spindle specification 1
Select the spindle specification.
A function is allocated to each bit.
Set this in hexadecimal format.
bit F-C : msr Motor series selection
0: 200V specification IM spindle motor
1: 200V specification IPM spindle motor
2: 400V specification IM spindle motor
3: 400V specification IPM spindle motor
4: 200V specification Tool spindle motor
Only "0" or "4" setting is available for MDS-D-SPJ3 Series.
- For MDS-DM Series
For MDS-DM-SPV2/SPV3, set to "0".
bit B-5 :
Not used. Set to "0".
bit 4 : fdir Position feedback
0: Forward polarity 1: Reverse polarity
bit 3 : vfb Speed feedback filter
0: Disable 1: Enable (2250Hz)
bit 2 : seqh READY ON sequence
0: Normal 1: High-speed
bit 1 : dfbx Dual feedback control
0: Stop 1: Start
bit 0 : fdir2 Speed feedback polarity
0: Forward polarity 1: Reverse polarity
msr
fdir
vfb
seqh
fdir2
dfbx