Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 20
3 Setup
MITSUBISHI CNC
#2217(PR) SV017 SPEC1 Servo specification 1
Select the servo specifications.
A function is allocated to each bit.
Set this in hexadecimal format.
bit F-C : spm Motor series selection
0: 200V HF, HP motor 1
1: 200V HF, HP motor 2 (Standard)
2: 400V HF-H, HP-H motor 1
3: 400V HF-H, HP-H motor 2 (Standard)
6: 200V LM-F linear motor
7: 200V direct-drive motor
8: 400V LM-F linear motor
9: 400V direct-drive motor
bit B :
Not used. Set to "0".
bit A : drvup Combined drive unit:
- For MDS-DM Series
0: Normal setting (Combined drive unit: normal)
1: Combined drive unit: one upgrade
In the following combination of the drive unit and servomotors, set to "bitA=1".
MDS-DM-V3-404040 --------- HF75, HF105, HF123, HF142
MDS-DM-SPV2/SPV3 --------- HF54, HF104, HF223, HF302
bit 9 :
Not used. Set to "0".
bit 8 : mp MPI scale pole number setting
0: 360 poles 1: 720 poles
bit 7 : abs Position control
These parameters are set automatically by the NC system.
0: Incremental 1: Absolute position control
bit 6-5 :
Not used. Set to "0".
bit 4 : sdir Sub side detector feedback
Set the machine side detector's installation polarity.
0: Forward polarity 1: Reverse polarity
bit 3 : vfb Speed feedback filter
0: Stop 1: Start (2250Hz)
bit 2 : seqh Ready on sequence
0: Normal 1: High-speed
abs
spm
mdir
dfbx
vfb
sdir
mp