Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 83
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-3 Setting the initial parameters for the spindle drive unit
<Relation of spindle limit rotation speed and spindle maximum rotation speed>
The spindle rotation speed which can be attained at the spindle motor's maximum rotation speed is set
for the limit rotation speed (slimt). This value is obtained by multiplying the gear ratio on the spindle
motor maximum rotation speed (SP026). Set the maximum rotation speed (smax) when the rotation
speed is to be limited according to the machine specifications, such as the spindle gear specifications.
Up to four value can be set for gear changeover.
<Relation of tap time constant and actual acceleration/deceleration time constant>
(For constant inclination synchronous tap cycle)
Set the acceleration time up to the tap rotation speed (stap) in the tap time constant (stapt).
Acceleration/deceleration is carried out at the same inclination for all speed commands. Up to four
values can be set for gear changeover.
SP026
0
smax
slimt1 smax2 smax
(
n
)
slimt2 slimt
(
n
)
1
Spindle motor rotation speed
(
r/min
)
S
p
indle rotation s
p
eed
(
r/min
)
stap(n)
0
Actual time stapt(n)
Time
(
ms
)
Actual
command
Spindle speed (r/min)