Mitsubishi Electronics IB-1500193(ENG)-D Home Theater Server User Manual


 
3 - 47
MDS-D-SVJ3/SPJ3 Series Instruction Manual
3-2 Setting the initial parameters for the servo drive unit
bit 5-4 : dfhz Notch filter frequency range
Set the adaptive range of the notch filter frequency. When the adaptive follow-up function is enabled
and if the estimated resonance frequency exists in the set range, the notch filter will be adapted.
Normally set this parameter to "00".
bit5,4=
00: -10 to 10 [%]
01: -20 to 20 [%]
10: -30 to 30 [%]
11: -40 to 40 [%]
bit 3-0 : esn Sensitivity of estimated resonance frequency
Set the sensitivity of the estimated resonance frequency. Smaller setting value enables to detect
smaller vibration component, however, adaptive movement will be repeated frequently. Normally set
this parameter to "0".
0 : Normal setting (same sensitivity as A) 1 : Sensitivity high to F : Sensitivity low
#2316 SV116 SSF11 Servo function 11
Not used. Set to "0000".
#2317(PR) SV117 RNG1ex Expansion sub side detector resolution
For high-accuracy binary resolution detector, set the number of pulses to four bite data of SV117
(high-order) and SV019 (low-order) by pulse(p).
When SV117=0, the setting unit of SV019 is (kp).
Refer to SV019 for details.
Related parameters: SV019, SV020, SV118
---Setting range---
-1 to 32767
#2318(PR) SV118 RNG2ex Expansion main side detector resolution
When using high-accuracy binary resolution detector, set the number of pulses to four bite data of
SV118 (high-order) and SV020 (low-order) by pulse(p).
When SV118=0, the setting unit of SV020 is (kp).
Refer to SV020 for details.
Related parameters: SV019, SV020, SV117
---Setting range---
-1 to 32767
#2319 SV119
Not used. Set to "0".
#2320 SV120
Not used. Set to "0".
#2321 SV121
Not used. Set to "0".
#2322 SV122
Not used. Set to "0".
#2323 SV123
Not used. Set to "0".