167
CHAPTER 7 PROGRAMMING
7
7.4 When Using the Module in a Remote I/O Network
7.4.4 Fixed-feed operation program
7.4.4 Fixed-feed operation program
This program executes positioning in the address increasing direction according to the specified movement amount
and speed. Execute fixed-feed operation by turning on Fixed-feed start command repeatedly. Use the current value
change function and positioning start in the absolute system. Suppose that parameter setting and OPR were
completed. ( Page 149, Section 7.4.1, Page 151, Section 7.4.2)
(1) Program detail
• As X32 is turned on, the following positioning data are written.
• As X33 is turned on, the module starts fixed-feed operation.
(2) Execution condition
Item Setting detail
Positioning address P1
20000pulse
Positioning speed V1
1000pulse/s
Check item Condition Note
External I/O
signal
Servo READY signal (READY) ON
Stop signal (STOP) OFF
Upper limit signal (FLS) ON
Lower limit signal (RLS) ON
I/O signal
QD73A1 READY signal (X1021) ON
BUSY signal (X1024) OFF
Excessive error signal (X1027) OFF
Error detection signal (X1028) OFF
Absolute positioning start complete signal
(X1031)
OFF
Synchronization flag (X1034) ON
Absolute positioning start signal (Y1031) OFF
Stop signal (Y1037) OFF
PLC READY signal (Y103D) ON
Buffer memory Positioning data No error
When the positioning speed is set
exceeding " Speed limit
value", the positioning is executed
at " Speed limit value".
Da.2
Da.3
Pr.5
Pr.5