CHAPTER 10 JOG OPERATION
10
10.3 Data Setting for JOG Operation
10.3 Data Setting for JOG Operation
To execute JOG operation, certain data must be set and stored in the buffer memory areas.
The following table lists the JOG data to be set, setting condition, and check timing.
Setting item Setting range
Default
value
Setting condition
Check timing
of the set
data
Buffer
memory
address
(decimal)
JOG speed 1 to 4000000pulse/s 0pulse/s
The data can be set anytime.
Note that the set data at the
rise (ON) of a JOG start
signal (Y24, Y25) are used
for the operation. If the data
are written when BUSY
signal (X14) is on, the data
will be accepted at the rise
(ON) of the next JOG start
signal (Y24, Y25).
When a JOG
start signal
(Y24, Y25) is
turned on
84
85
Speed limit value
10 to 4000000pulse/s
(Set in the unit of
10pulse/s.)
200000
pulse/s
20
21
Acceleration time
2 to 9999ms 300ms
22
Deceleration time 23
Cd.3
Pr.5
Pr.6
Pr.7