Mitsubishi Electronics QD73A1 Universal Remote User Manual


 
94
Immediate stop
accumulated pulse
setting value (maximum
value)
The difference between the reference value
(maximum value) and the judgment value
(immediate stop accumulated pulses
(maximum value)) is set.
The relation between this setting and the
judgment value is as follows.
[If " Accumulated pulse setting value
selection" is set to 0]
Immediate stop accumulated pulses
(maximum value) = reference value
(maximum value) + Immediate stop
accumulated pulse setting value (maximum
value)
[If " Accumulated pulse setting value
selection" is set to 1]
Immediate stop accumulated pulses
(maximum value) = reference value
(maximum value) + ( Immediate stop
accumulated pulse setting value (maximum
value) - 1000) × reference value (maximum
value) 1000
For details on the accumulated pulse error
detection function, refer to the following.
Page 223, Section 11.9
• If " Accumulated
pulse setting value
selection" is set to 0:
1 to 148000 pulse
• If " Accumulated
pulse setting value
selection" is set to 1:
1000 to 50000
(× 10
-3
: Last three digits
are the value after the
decimal point.)
0
402
403
Item Description Setting range
Default
value
Buffer
memory
address
(decimal)
Cd.14
Cd.17
Cd.14
Cd.17
Cd.14
Cd.17
Cd.17