259
CHAPTER 14 TROUBLESHOOTING
14
14.3 Details of Errors
14.3.4 Error code list
Zero/gain
adjustment
error
120
ERR.1
Flash ROM write
exceeded
For zero/gain
adjustment, a setting
value has been
consecutively written
to the flash ROM more
than 25 times.
The zero/gain
adjustment values
are not reflected.
Turn off and on the
power supply, or reset
the CPU module or the
error.
121
Flash ROM write
error
For zero/gain
adjustment, the
setting value could not
be written in the flash
ROM.
Try writing the value
again.
If the error occurs
again, a failure might
have occurred on the
module. Please consult
your local Mitsubishi
representative.
122
Zero adjustment
error
For zero/gain
adjustment, the zero
adjustment value is
equal to or greater
than the gain
adjustment value.
Set the values so that
they meet the following
condition: Zero
adjustment value <
Gain adjustment value
123
Zero/gain
adjustment
setting error
The set value in
" Zero/gain
adjustment
specification" is
outside the setting
range.
Set a value within the
setting range (1, 2) in
" Zero/gain
adjustment
specification".
124
Zero/gain
adjustment
value error
The set value in
" Zero/gain
adjustment value
specification" is
outside the setting
range.
Set a value within the
setting range (-3000 to
3000) in "
Zero/gain adjustment
value specification".
Error
category
Error
code
(decimal)
Error
classification
Error name Description
Operation at the
error occurrence
Action
Cd.10
Cd.10
Cd.11
Cd.11