97
CHAPTER 5 DATA USED FOR POSITIONING
5
5.6 Control Data
Accumulated pulse error
detection request
• Use this area to start/stop the accumulated
pulse error detection function.
• While this area is set to 1, the accumulated
pulse error detection function is executed.
However, if the reference value has never
been measured, the error "Accumulated
pulse error undetectable" (error code: 131)
occurs and the function does not operate.
• If a value other than 0 and 1 is set, the value
is regarded as 0.
• If " Measurement start request" is set
to 1, the function does not operate even if
this area is set to 1. (This request is ignored
and after " Measurement start
request" is set to 0, the function is
executed.)
For details on the accumulated pulse error
detection function, refer to the following.
Page 223, Section 11.9
0: No request
1: Requested
0: No
request
409
Measurement start
request
• Use this area to measure accumulated
pulses used as the reference value to detect
an error.
• While this area is set to 1, the
maximum/minimum accumulated pulse
values are measured.
• If a value other than 0 and 1 is set, the value
is regarded as 0.
• If " Accumulated pulse error detection
request" is set to 1, the value is not
measured even if this area is set to 1. (This
request is ignored and after
" Accumulated pulse error detection
request" is set to 0, the function is
executed.)
For details on the accumulated pulse error
detection function, refer to the following.
Page 223, Section 11.9
0: No request
1: Requested
0: No
request
410
Item Description Setting range
Default
value
Buffer
memory
address
(decimal)
Cd.18
Cd.19
Cd.19
Cd.19
Cd.18
Cd.18