CHAPTER 5 DATA USED FOR POSITIONING
5
5.6 Control Data
Alert output
accumulated pulse
setting value (maximum
value)
The difference between the reference value
(maximum value) and the judgment value
(alert output accumulated pulses (maximum
value)) is set.
The relation between this setting and the
judgment value is as follows.
[If " Accumulated pulse setting value
selection" is set to 0]
Alert output accumulated pulses (maximum
value) = reference value (maximum value) +
Alert output accumulated pulse setting
value (maximum value)
[If " Accumulated pulse setting value
selection" is set to 1]
Alert output accumulated pulses (maximum
value) = reference value (maximum value) +
( Alert output accumulated pulse setting
value (maximum value) - 1000) × reference
value (maximum value) 1000
For details on the accumulated pulse error
detection function, refer to the following.
Page 223, Section 11.9
• If " Accumulated
pulse setting value
selection" is set to 0:
1 to 148000 pulse
• If " Accumulated
pulse setting value
selection" is set to 1:
1000 to 50000
(× 10
-3
: Last three digits
are the value after the
decimal point.)
0
400
401
Item Description Setting range
Default
value
Buffer
memory
address
(decimal)
Cd.13
Cd.17
Cd.13
Cd.17
Cd.13
Cd.17
Cd.17