176
(3) Deviation counter clearing program
This program clears the deviation counter to 0.
(a) Program detail
As X39 is turned on, the deviation counter is cleared to 0.
(b) Execution condition
(c) Device used by the user
(d) Program example
Item Setting detail
Deviation counter clear command
1: Clear the deviation counter
Check item Condition Note
I/O signal
WDT error, H/W error signal (X1020) OFF
BUSY signal (X1024) OFF
Error detection signal (X1028) OFF
Synchronization flag (X1034) ON
Device Description
X39 Deviation counter clear command
D110 Deviation counter clear request
D111 Deviation counter clearing result check
M80 Deviation counter clear
M81 Deviation counter clearing completion check
M300 Z(P).REMTO instruction completion
M301 Z(P).REMTO instruction failure
M302 Z(P).REMFR instruction completion
M303 Z(P).REMFR instruction failure
Cd.4
Command deviation counter clear.
Deviation counter clear command
Command deviation counter clear to the
QD73A1.
Completes the deviation counter clear
command.
Command to check the deviation counter
clear.
Command to check the deviation counter
clear again when it is incomplete.
Completes reading the deviation counter
clear.
Read the completion of deviation counter
clear from the QD73A1.