Mitsubishi Electronics QD73A1 Universal Remote User Manual


 
84
(3) Positioning speed V1
Set the command speed of major positioning control. Set a value equal to or less than " Speed limit value".
If the value exceeds " Speed limit value", the error "Positioning speed Outside the setting range" (error
code: 32) occurs, and the command speed is limited to " Speed limit value".
If the specified positioning speed is 0, the error "Positioning speed Outside the setting range" (error code: 32)
occurs, and the positioning does not start.
(4) Positioning address P2
This setting is enabled only for two-phase trapezoidal positioning control.
Set the destination address of after the move to the address set to " Positioning address P1".
For details on " Positioning address P1", refer to the following.
Page 83, Section 5.4 (2)
(5) Positioning speed V2
This setting is enabled only for two-phase trapezoidal positioning control.
Set the command speed to move to the address set to " Positioning address P2".
The setting condition is the same as that of " Positioning speed V1". ( Page 84, Section 5.4 (3))
Da.3
Pr.5
Pr.5
Pr.5
Da.4
Da.2
Da.2
Da.5
Da.4
Da.3