14.3.4 Error code list
The following table describes error details and corrective actions.
Error
category
Error
code
(decimal)
Error
classification
Error name Description
Operation at the
error occurrence
Action
Setting data
range error
(Fixed
parameter)
1
ERR.1
Stroke limit
lower limit
The set value in
" Stroke limit
lower limit" is outside -
2147483648 to
" Stroke limit
upper limit".
If a setting is outside
the setting range,
the error occurs and
all of the fixed
parameters use the
default values for
the control.
Set a value within the
setting range, and turn
on PLC READY signal
(Y2D).
2
Numerator of
command pulse
multiplication for
electronic gear
Outside the
setting range
The set value in
" Numerator of
command pulse
multiplication for
electronic gear" is
outside the setting
range.
Set a value within the
setting range, and turn
on PLC READY signal
(Y2D).
[Setting range]
1 to 9999
3
Denominator of
command pulse
multiplication for
electronic gear
Outside the
setting range
The set value in
" Denominator
of command pulse
multiplication for
electronic gear" is
outside the setting
range.
Set a value within the
setting range, and turn
on PLC READY signal
(Y2D).
[Setting range]
1 to 9999, and besides
1/50 CMX/CDV 50
Setting data
range error
(Variable
parameter)
10
Speed limit
value Outside
the setting range
The set value in
" Speed limit
value" is outside the
setting range.
Only the setting with
the error uses the
default value for
control.
Set a value within the
setting range.
[Setting range]
10 to 4000000pulse/s
11
Acceleration
time Outside the
setting range
The set value in
" Acceleration
time" is outside the
setting range.
Set a value within the
setting range.
[Setting range]
2 to 9999ms
12
Deceleration
time Outside the
setting range
The set value in
" Deceleration
time" is outside the
setting range.
Set a value within the
setting range.
[Setting range]
2 to 9999ms
13
In-position range
Outside the
setting range
The set value in
" In-position
range" is outside the
setting range.
Set a value within the
setting range.
[Setting range]
1 to 20479pulse
14
Positioning
mode Outside
the setting range
The set value in
" Positioning
mode" is other than 0
and 1.
Set a value within the
setting range.
Pr.2
Pr.1
Pr.3
Pr.4
Pr.5
Pr.6
Pr.7
Pr.8
Pr.9