(3) Setting the speed limit function
The following table lists the data to be set, setting condition, and check timing.
Set " Speed limit value" in a unit of 10 pulses. If a single digit is set, the value is rounded off.
For instance, if "1999" is set, the operation is executed with a speed limit value of "1990".
Setting item Setting range Default value Setting condition
Check timing of the
set data
Buffer
memory
address
(decimal)
Speed limit
value
10 to
4000000pulse/s
(Set in the unit of
10pulse/s.)
200000 pulse/s
The data can be set
anytime.
Note that the set data at
the rise (ON) of a start
signal is used for the
operation. If the data is
written when BUSY
signal (X14) is on, the
data will be accepted at
the rise (ON) of the next
start signal.
• When a positioning start
signal (Y21 to Y23) is
turned on
• When a JOG start
signal (Y24, Y25) is
turned on
• When OPR start signal
(Y20) is turned on
20
21
Pr.5
Pr.5
Ex.