Mitsubishi Electronics QD73A1 Universal Remote User Manual


 
95
CHAPTER 5 DATA USED FOR POSITIONING
5
5.6 Control Data
Alert output
accumulated pulse
setting value (minimum
value)
The difference between the reference value
(minimum value) and the judgment value (alert
output accumulated pulses (minimum value))
is set.
The relation between this setting and the
judgment value is as follows.
[If " Accumulated pulse setting value
selection" is set to 0]
Alert output accumulated pulses (minimum
value) = reference value (minimum value) +
Alert output accumulated pulse setting
value (minimum value)
[If " Accumulated pulse setting value
selection" is set to 1]
Alert output accumulated pulses (minimum
value) = reference value (minimum value) +
( Alert output accumulated pulse setting
value (minimum value) - 1000) × reference
value (minimum value) 1000
For details on the accumulated pulse error
detection function, refer to the following.
Page 223, Section 11.9
• If " Accumulated
pulse setting value
selection" is set to 0:
-148000 to -1 pulse
• If " Accumulated
pulse setting value
selection" is set to 1:
1000 to 50000
(× 10
-3
: Last three digits
are the value after the
decimal point.)
0
404
405
Item Description Setting range
Default
value
Buffer
memory
address
(decimal)
Cd.15
Cd.17
Cd.15
Cd.17
Cd.15
Cd.17
Cd.17