5 DATA USED FOR POSITIONING CONTROL
Da.14
Condition target
Set the condition target as required for each control.
Setting value Setting details
01H : Device X
Set the input/output signal ON/OFF as the conditions.
02H : Device Y
03H : Buffer memory (1-word) Set the value stored in the buffer memory as the condition.
03H: The target buffer memory is "1-word (16 bits)"
04
H: The target buffer memory is "2-word (32 bits)"
04H : Buffer memory (2-word)
05H : Positioning data No. Select only for "simultaneous start".
Da.15
Condition operator
Set the condition operator as required for the "
Da.14 Condition target".
Da.14
Condition target
Setting value Setting details
01H : Device X
02
H : Device Y
07
H : DEV=ON
When the input/output signal ON/OFF is set as the
condition, set "ON" or "OFF".
08H : DEV=OFF
03H : Buffer memory (1-word)
04
H : Buffer memory (2-word)
01H :

=P1
Set how to judge the conditions for the value (
)
target stored in the buffer memory.
06H :

P1, P2
05H : Positioning data No.
09
H : Axis 1 designation
Set the axis to start simultaneously when
"simultaneous start" is selected.
0AH : Axis 2 designation
Da.16
Address
Set the address as required for the "
Da.14 Condition target".
Da.14
Condition target
Setting value Setting details
01H : Device X
Not used. (There is no need to set.)
02H : Device Y
03H : Buffer memory (1-word)
Value
(Buffer memory address)
Set the target "buffer memory address".
(For 2 word, set the low-order buffer memory
address.)
04H : Buffer memory (2-word)
05H : Positioning data No. Not used. (There is no need to set.)