11 - 5
MELSEC-
A
11 MANUAL CONTROL
Precautions during operation
The following details must be understood before carrying out JOG operation.
(1) For safety, first set "JOG speed (RWwm+6 to 7, RWwm+14 to 15)" to a
smaller value and check the movement. Then gradually increase the value.
(2) If "JOG speed (RWwm+6 to 7, RWwm+14 to 15)" exceeds the speed set in
"
Pr.32 JOG speed limit value", the workpiece will move at the " Pr.32 JOG
speed limit value" and a warning "JOG speed limit value" (warning code: 301)
will occur in the D75P2.
(3) The JOG operation can be continued even if a warning "JOG speed limit
value" (warning code: 301) has occurred.
(4) A JOG start signal OFF
ON immediately after the stop signal ON OFF
(within 56.8ms) will be ignored. (The operation will not start.)
Errors during operation
When the operation is stopped by the stroke limit (limit signal OFF), JOG operation
can be performed after an error reset in the direction in which the limit signal turns
ON. (The error will occur again if the JOG start signal in the direction in which the
limit signal turns OFF is turned ON.)
JOG operation possible
JOG operation not possible
JOG operation
V
ON
OFF
Upper/lower
limit signal