MELSEC-
A
12 CONTROL AUXILIARY FUNCTIONS
(7) Setting when the control unit is "degree"
Current value address
The "Current feed value (RWrn+0 to 1, RWrn+8 to 9)" address is ring addresses
between 0 and 359.99999
°
.
359.99999° 359.99999°
Fig. 12.17 Current value address when the control unit is "degree".
Setting the software stroke limit
The upper limit value/lower limit value of the software stroke limit is a value
between 0 and 359.99999
°
.
(1) Setting when the software stroke limit is to be validated.
When the software stroke limit is to be validated, set the upper limit value in a
clockwise direction from the lower limit value.
Section A
315º
Set in a clockwise direction
Upper limit
L
ower limit
90º
Section B
(a) Set the movement range of section A as follows.
Software stroke limit lower limit value ................ 315.00000
°
.
Software stroke limit upper limit value ................ 90.00000
°
.
(b) Set the movement range of section B as follows.
Software stroke limit lower limit value ................ 90.00000
°
.
Software stroke limit upper limit value ................ 315.00000
°
.
Fig. 12.18 Software stroke limit when the control unit is "degree"