5 - 111
MELSEC-
A
5 DATA USED FOR POSITIONING CONTROL
Setting value Default value
Storage buffer
memory address
Axis 1 Axis 2
Set with a decimal.
K 1
Continuous operation interrupt request
Setting value
After the control interrupt request is accepted, "0" is stored by the OS.
(Indicates that the continuous operation interrupt request is completed.)
1: Interrupt continuous control or continuous
path control. (Set by sequence program)
0 1181 1231
Set with a decimal.
Setting value
To set "60000ms" for the "
New acceleration time value", set
"60000" in the buffer memory.
Example)
Cd.33
Cd.33 New acceleration time value
Cd.34 New deceleration time value
0
1184
1185
1234
1235
0
1186
1187
1236
1237
Set with a decimal.
K
Acceleration/deceleration time change during
speed change, enable/disable selection
Setting value
1: Enable acceleration/deceleration time
change
Other than 1: Disable acceleration/
deceleration time chan
g
e
0 1188 1238
Set with a decimal.
K
Speed/position changeover control
(ABS mode) function valid flag
Setting value
0: INC mode
1: ABS mode
0 1188 1238