Mitsubishi Electronics AJ65BT-D75P2-S3 Universal Remote User Manual


 
12 - 36
MELSEC-
A
12 CONTROL AUXILIARY FUNCTIONS
(1) Control details
The following drawing shows the operation during a speed change.
V
V1
V2
V3
t
Speed changes to V2.
Operation during
positioning by V1.
Speed changes to V3.
In speed change processing flag
(
RX
(
n+1
)
1, RX
(
n+4
)
1
)
Fig. 12.22 Speed change operation
(2) Precautions during control
(a) For the speed change during the continuous path control, the following
control is performed.
1) When no speed designation (current speed) is provided in the next
positioning data:
The next positioning data is controlled at the "New speed value
(RWwm+4 to 5, RWwm+12 to 13)".
2) When a speed designation (current speed) is provided in the next
positioning data:
The next positioning data is controlled at its command speed
(
Da.7 ).
Positioning control
P1
Designated speed in P2
New speed value
(RWwm+4 to 5, RWwm+12 to 13)
Next control
P2
Speed change
command
Designated speed in P1
[a] When no speed designation
(current speed) is provided.
[b] When a speed designation
is provided.
Fig. 12.23 Speed change during continuous path control
(b) When changing the speed during continuous path control, the speed change
will be ignored if there is not enough distance remaining to carry out the
change.