5 DATA USED FOR POSITIONING CONTROL
Setting item Setting details
Cd.8
Read/write positioning data
I/F*
1
Store the data when reading or writing.
Cd.9
Flash ROM write request*
2
Write the OS memory contents into the flash ROM.
Cd.10
Parameter initialization
request
*
2
Set whether the setting data will be initialized or not.
Initialization: Indicates that the setting values of the setting data are returned to
the default values.
Note) After completion of the setting data initialization processing, reset the
D75P2 to initialize the setting data of the buffer memory.
Initialized setting data
Parameter (
Pr.1
to
Pr.58
)
Positioning data (No. 1 to 600)
Positioning start information (No. 7000 to 7010)
*
1
Cd.4
to
Cd.8
are data used to transmit the positioning data between the OS memory and buffer memory.
(Refer to section "7.2 Data transmission process".)
*
2
During execution of a flash ROM write request or parameter initialization request (this also applies to the "flash ROM request"
using the AD75 software package"), a transient transmission request such as the dedicated command (RIRD, RIWT) cannot
be accepted. A "response error" (error code: B404) will occur on the master station side if a transient transmission request is
executed during execution of a flash ROM write request or parameter initialization request.
If there is a possibility that a transient transmission request may be executed during execution of a flash ROM write request or
parameter initialization request, create a sequence program so that a transient transmission request will be executed again at
occurrence of a response error. (The processing time necessary for normal completion of flash ROM write or parameter
initialization is a maximum of 35s. Use this as a guideline for setting the retry count and response monitoring time.)