14 - 15
MELSEC-
A
14 TROUBLESHOOTING
Relevant buffer memory address
remote input/output device, or
remote register
Setting range Remedy
Axis 1 Axis 2
Refer to section “5.4 List of start
block data.”
<Condition data No.>
1 to 10
Examine the condition data number. (Refer to
Da.13
in
section 5.4)
Refer to section “5.5 List of
condition data.”
<Condition operator>
Axis designation: 09
H, 0AH
Correct the condition operator.
(Refer to section 5.5 Da.15)
RWwm RWwm+8
<Positioning start No.>
1 to 600, 7000 to 7010, 9001 to 9003,
9900 or 9901
Correct the positioning start number.
Refer to section “5.3 List of
positioning data.”
<Command speed>
(In standard mode)
1 to 1000000 [pulse/s]
1 to 600000000 [mm/min, etc.]
(In stepping motor mode)
1 to 62500 [pulse/s]
1 to 37500000 [mm/min, etc.]
Correct the positioning data.