Mitsubishi Electronics AJ65BT-D75P2-S3 Universal Remote User Manual


 
9 - 21
MELSEC-
A
9 MAIN POSITIONING CONTROL
Limits to interpolation control
There are limits to the interpolation control that can be executed and speed
(
Pr.21 Interpolation speed designation method) that can be set, depending on
the "
Pr.1 Unit setting" of the reference axis and interpolation axis. (For
example, circular interpolation control cannot be executed if the reference axis and
interpolation axis units differ.)
The following table shows the interpolation control and speed designation limits.
" Da.2 Control method"
interpolation control
Pr.21 Interpolation speed
designation method
Pr.1 Unit setting *
1
Reference axis and interpolation
axis units are the same, or a
combination of "mm" and "inch".
Reference axis and
interpolation axis units
differ *
3
Linear 2 (ABS, INC)
Fixed-dimension feed 2
Composite speed
Reference axis speed
Circular interpolation (ABS, INC)
Right arc (ABS, INC)
Left arc (ABS, INC)
Composite speed
*
2
Reference axis speed
: Setting possible, : Setting not possible.
*
1
"mm" and "inch" unit mix possible.
*
2
"degree" setting not possible. An error "control method setting error" (error code: 524) will occur and the position
cannot start if circular interpolation control is set when the unit is "degree". The machine will immediately stop if
"degree" is set during positioning control.
*
3
The unit set in the reference axis will be used for the speed unit during control if the units differ or if "mm" and "inch"
are combined.
Axis operation status during interpolation control
"In interpolation" will be stored in the "Axis operation status (RWrn + 7, Rwrn + 15)"
during interpolation control. "Standing by" will be stored when the interpolation
operation is terminated. Both the reference axis and interpolation axis will carry out
a deceleration stop if an error occurs during control, and "error occurring" will be
stored in the operation status.