12 - 74
MELSEC-
A
12 CONTROL AUXILIARY FUNCTIONS
(2) Setting the stepping motor mode function
To use the "stepping motor mode function", set the required values in the
parameters shown in the following table, and write them to the D75P2.
The set details are validated at the rising edge (OFF
ON) of the remote station
READY signal [RX(n+7)B].
Setting item
Setting
value
Setting details
Factory-set
initial value
Pr.10
Bias speed at
start
Set the minimum speed during start. 0
Pr.11
Stepping motor
mode selection
1 Set "1: stepping motor mode". 0
* Refer to section "5.2 List of parameters" for setting details.
REMARK
Parameters are set for each axis.