9 - 32
MELSEC-
A
9 MAIN POSITIONING CONTROL
Restrictions
(1) An error "Continuous path control not possible" (error code: 516) will occur and
the operation cannot start if "continuous path control" is set in "
Da.1 Operation
pattern". ("Continuous path control" cannot be set in fixed-dimension feed control.)
(2) If the movement amount of each axis exceeds "1073741824 (=2
30
)" at the
setting of "0: Composite speed" in "
Pr.21 Interpolation speed designation
method", an error "outside linear movement amount range" (error code: 504)
will occur at a positioning start and positioning cannot be started. (The maximum
movement amount that can be set in "
Da.5
Positioning address/movement
amount" is "1073741824 (=2
30
)".
(3) "Fixed-dimension feed" cannot be set in "
Da.2 Control method" in the
positioning data when "continuous path control" has been set in "
Da.1
Operation pattern" of the immediately prior positioning data. (For example, if
the operation pattern of positioning data No. 1 is "continuous path control",
fixed-dimension feed control cannot be set in positioning data No. 2.) An error
"Continuous path control not possible" (error code: 516) will occur and the
machine will carry out a deceleration stop if this type of setting is carried out.
Positioning data setting example
The following table shows setting examples when "2-axis fixed-dimension feed
control (fixed-dimension feed 2)" is set in positioning data No. 1 of axis 1. (The
required values are also set in positioning data No. 1 of axis 2.)
Axis
Setting item
Axis 1
(reference
axis) setting
example
Axis 2
(interpolation
axis) setting
example
Setting details
Axis 1 Positioning data No. 1
Da.1
Operation pattern
Positioning
complete
–
Set "Positioning complete" assuming the next positioning
data will not be executed.
Da.2
Control method
Fixed-
dimension
feed 2
– Set 2-axis fixed-dimension feed control.
Da.3
Acceleration time
No.
1 –
Designate the value set in "
Pr.26 Acceleration time 1" as
the acceleration time at start.
Da.4
Deceleration time
No.
0 –
Designate the value set in "
Pr.9 Deceleration time 0" as
the deceleration time at deceleration.
Da.5
Positioning address/
movement amount
80000.0
m
60000.0
m
Set the positioning address. (Assuming "mm" is set in
"
Pr.1 Unit setting".)
Da.6
Arc address – – Setting not required (setting value will be ignored).
Da.7
Command speed
6000.00
mm/min
–
Set the speed during movement. (Designate the composite
speed of reference axis speed in "
Pr.21 Interpolation
speed designation method".)
Da.8
Dwell time 500ms –
Set the time the machine dwells after the positioning stop
(pulse output stop) to the output of the positioning complete
signal.
Da.9
M code 10 –
Set this when other auxiliary operation commands are
issued in combination with the No. 1 positioning data.
* Refer to section "5.3 List of positioning data" for information on the setting details.
POINT
The speed limit does not function for the speed calculated by the D75P2 during interpolation control.
Because of this, observe the following precautions when setting the speed.
When the "composite speed" is set, set a value so the speed for each axis does not exceed the
"
Pr.7 Speed limit value".
When the "reference axis speed" is set, set so the major axis side becomes the reference axis. If
the minor axis side is set as the reference axis, the major axis side speed may exceed the "