5 - 105
MELSEC-
A
5 DATA USED FOR POSITIONING CONTROL
Setting value Default value
Storage buffer
memory address
(common for axis 1 to
axis 2)
Each stored item is stored in the following storage address.
1117 1127
1116 1126
1115 1125
1114 1124
1113 1123
1112 1122
1111 1121
1110 1120
1109 1119
1108 1118
Arc address
Storage address
Axis 1 Axis 2
Stored item
Reference
Positioning identifier
M code
Dwell time
Not used
Command speed
Positioning address
to
Da.1
Da.4
Da.9
Da.8
Da.7
Da.5
Da.6
0 1108 to 1137
Set with a decimal.
K
1
Flash ROM write request
Setting value
After writing is completed, "0" is stored by the OS.
(Indicates that the writing is completed.)
1: Flash ROM write request
(Set by sequence program)
0 1138
Set with a decimal.
K
Parameter initialization request
Setting value
After initialization, "0" is stored by the OS.
(Indicates that the writing is completed.)
0: Parameter initialization no-executio
n
1: Parameter initialization request
(Set by sequence program)
0 1139