Mitsubishi Electronics AJ65BT-D75P2-S3 Universal Remote User Manual


 
10 - 2
MELSEC-
A
10 ADVANCED POSITIONING CONTROL
10.1 Outline of advanced positioning control
In "advanced positioning control" the execution order and execution conditions of the
"positioning data" are set to carry out more applied positioning. (The execution order
and execution conditions are set in the "start block data" and "condition data".)
The following applied positioning controls can be carried out with "advanced
positioning control".
Advanced
positioning control
Details
Block* start
(Normal start)
With one start, executes the positioning data in a random block with the set
order.
Condition start
Carries out condition judgment set in the "condition data" for the
designated positioning data, and then executes the "start block data".
When the condition is established, the "start block data" is executed. When
not established, that "start block data" is ignored, and the next point's "start
block data" is executed.
Wait start
Carries out condition judgment set in the "condition data" for the
designated positioning data, and then executes the "start block data".
When the condition is established, the "start block data" is executed. When
not established, stops the control until the condition is established. (Waits.)
Simultaneous start
Simultaneously executes the positioning data having the No. for the axis
designated with the "condition data". (Outputs pulses at the same timing.)
Stop Stops the positioning operation.
Repeated start
(FOR loop)
Repeats the program from the "start block data" set with the "FOR loop" to
the "start block data" set in "NEXT" for the designated No. of times.
Repeated start
(FOR condition)
Repeats the program from the "start block data" set with the "FOR
condition" to the "start block data" set in "NEXT" until the conditions set in
the "condition data" are established.
Advanced positioning control auxiliary functions
"Advanced positioning control" uses the "positioning data" set with the "main
positioning control". Refer to "3.3.4 Combination of D75P2 main functions and
auxiliary functions" for details on auxiliary functions that can be combined with the
main positioning control.
Advanced positioning control from peripheral devices
"Advanced positioning control" (start of the "start block data") can be executed
from the AD75 software package test mode.
Refer to the AD75 Software Package Operating Manual for details on starting of
the "start block data" from the AD75 software package.
REMARK
Block *:
"1 block" is defined as all the data continuing from the positioning data in which
"continuous positioning control" or "continuous path control" is set in the
operation pattern (
Da.1 ) to the positioning data in which "independent
positioning control (Positioning complete)" is set.