Item
CC-Link station type Intelligent device station
Number of occupied
stations
4 stations (RX/RY 128 points each, RWr/RWw 16 points each)
External power supply (V) 24VDC (20.4 to 26.4VDC)
Applicable conductor size
(mm
2
)
0.75 to 2.00mm
2
Module mounting screw
(mm)
M4 0.7mm 16mm or more
DIN rail can also be used for mounting.
Applicable DIN rail TH35-7.5Fe, TH35-7.5AI, TH35-15Fe (compliant with JIS C 2812)
Applicable crimping
terminal
RAV1.25-3.5, RAV2-3.5
Internal current
consumption (24VDC) (A)
0.30A
Flash ROM write count Maximum 100,000 times
Noise immunity
Noise voltage 500Vp-p, noise width 1
s
(by noise simulator of 25 to 60Hz noise frequency)
Dielectric withstand
voltage
500VAC for 1 minute across power supply/communication system and external input/output
Insulation resistance
10M
or more by 500VDC insulation resistance tester across power supply/communication
system and external input/output
Outline dimensions (mm) 63.5 (H) 170 (W) 80 (D)mm
Weight (kg) 0.50kg
*
1
When a stepping motor is used, the circular interpolation function cannot be used.
*
2
The control unit of speed/position changeover control in the absolute system is "degree" only.
(For details, refer to section "9.2.9 Speed/position changeover control".)
*
3
Indicates the setting range in the "standard mode/stepping motor mode".
*
4
When a stepping motor is used, S-curve acceleration/deceleration cannot be used.