9 - 57
MELSEC-
A
9 MAIN POSITIONING CONTROL
Positioning data setting examples
The following table shows setting examples when "current value change" is set in
positioning data No. 1 of axis 1.
Setting item Setting example Setting details
Positioning data No. 1
Da.1
Operation pattern
Positioning
complete
Set "Positioning complete" assuming the next positioning data will not
be executed. ("Continuous path control" cannot be set in current value
change.)
Da.2
Control method
Current value
change
Set the current value change.
Da.3
Acceleration time No. 1
Designate the value set in " Pr.26 Acceleration time 1" as the
acceleration time at start.
Da.4
Deceleration time No. 0
Designate the value set in "
Pr.9 Deceleration time 0" as the
deceleration time at deceleration.
Da.5
Positioning address/
movement amount
10000.0
m
Set the movement amount after the changeover to position control.
(Assuming that the "
Pr.1 Unit setting" is set to "mm".)
Da.6
Arc address – Setting not required. (Setting value is ignored.)
Da.7
Command speed 6000.00mm/min Set the speed to be controlled.
Da.8
Dwell time – Setting not required. (Setting value is ignored.)
Da.9
M code 10
Set this when other auxiliary operation commands are issued in
combination with the No. 1 positioning data.
* Refer to section "5.3 List of positioning data" for information on the setting details.