Mitsubishi Electronics AJ65BT-D75P2-S3 Universal Remote User Manual


 
5 - 110
MELSEC-
A
5 DATA USED FOR POSITIONING CONTROL
Setting item Setting details
Cd.32
Interrupt request during
continuous operation
To interrupt the operation during continuous operation, set "1".
(In the non-operation mode (when the BUSY signal [RXn4, RXn5] is OFF), the
interrupt request during continuous operation is not accepted.)
Cleared to 0 at a start or at a restart.
If the interrupt request is received after setting "1", "0" will be automatically stored
by the OS.
Cd.33
New acceleration time value
When changing the acceleration time during speed change, set the new
acceleration time.
Pr.25
setting
Cd.33
setting range (unit)
1-word type 0 to 65535 (mm)
2-word type 0 to 8388608 (ms)
Cd.34
New deceleration time value
When changing the deceleration time during speed change, set the new
deceleration time.
Pr.25
setting
Cd.33
setting range (unit)
1-word type 0 to 65535 (mm)
2-word type 0 to 8388608 (ms)
Cd.35
Acceleration/deceleration
time change during speed
change, enable/disable
selection
Set whether to enable/disable the acceleration/deceleration time change during
speed change.
Cd.36 Speed/position changeover
control (ABS mode) function
valid flag
Set the INC mode or ABS mode of speed/position changeover control.