Mitsubishi Electronics AJ65BT-D75P2-S3 Universal Remote User Manual


 
6 - 48
MELSEC-
A
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
*
*No. 5 Zero point return request OFF program
*
*
*No. 6 External start function valid setting program
*
Turn ON Axis 1 zero
point return request OFF
request
Axis 1 external start valid
Axis 1 external start
invalid
*
*No. 7 Positioning start number setting program
*
*
*(1) Machine zero point return
*
*
*(2) Data setting method zero point return
*
*
*(3) High-speed zero point return
*
Write machine zero
point return (9001)
Write data setting method
zero point return (9901)
Write high-speed zero
point return (9002)
Hold High-speed zero
point return command
*
*(4) Positioning data No. 1-based positioning (other than speed/position changeover control)
*
Write positioning data
No. 1
*
*(5) Positioning data No. 1-based positioning (speed/position changeover control)
*
*
*(6) Advanced positioning control
*
*
*(7) High-speed zero point return command storage OFF
*(Not required when high-speed zero point return is not used)
*
Write positioning data
No. 1
Write block positioning
(7000)
Turn OFF High-speed
zero point return
command storage
Enable Speed/position
changeover
Disable Speed/position
changeover