12 - 23
MELSEC-
A
12 CONTROL AUXILIARY FUNCTIONS
(2) Precautions during control
During interpolation control, speed limiting is carried out at the reference axis
side setting value.
(The speed limit will not function on the interpolation side.)
(3) Setting the speed limit function
To use the "speed limit function", set the "speed limit value" in the parameters
shown in the following table, and write them to the D75P2.
The set details are validated after they are written to the D75P2.
Setting item
Setting
value
Setting details
Factory-set
initial value
Pr.7 Speed limit value
Set the speed limit value (max. speed during control). 0
Pr.32
JOG speed limit
value
Set the speed limit value during JOG operation (max.
speed during control). (Note that "
Pr.32 JOG speed
limit value" shall be less than or equal to "
Pr.7
Speed limit value".)
0
* Refer to section "5.2 List of parameters" for setting details.
REMARK
Parameters are set for each axis.