Mitsubishi Electronics AJ65BT-D75P2-S3 Universal Remote User Manual


 
3 - 24
MELSEC-
A
3 SPECIFICATIONS AND FUNCTIONS
(2) Remote register details
Setting item Setting details
Positioning start No. • Set the start No. for positioning.
Positioning operation speed override
Set the "override" value when overriding the speed during positioning operation.
*For details of "override", refer to section "12.5.2 Override function".
New current value
• Set a new current feed value when changing the current feed value using the
start No. "9003".
• The setting value should be within the following range.
Pr.1
Pr.11
mm
(
10
-1
μm)
inch
( 10
-5
inch)
degree
( 10
-5
degree)
pulse
(pulse)
Standard
mode
-2147483648 to
+2147483647
-2147483648 to
+2147483647
0 to 35999999
-2147483648 to
+2147483647
Stepping
motor mode
-134217728 to
+134217727
-134217728 to
+134217727
0 to 35999999
-134217728 to
+134217727
New speed value
• Set a new speed when changing the speed.
• Setting "0" makes a stop.
• The setting value should be within the following range.
Pr.1
Pr.11
mm
(
10
-2
mm/min)
inch
( 10
-3
inch/min)
degree
(
10
-3
degree/min)
pulse
(pulse/s)
Standard
mode
0 to 600000000 0 to 600000000 0 to 600000000 0 to 1000000
Stepping
motor mode
0 to 37500000 0 to 37500000 0 to 37500000 0 to 62500