1 - 11
MELSEC-
A
1 PRODUCT OUTLINE
D75P2 Peripheral device
The D75P2 and peripheral device communicate the following data via the peripheral
device connection connector.
Direction
Communication
D75P2
Peripheral device Peripheral device D75P2
Data (read/write)
Parameter, positioning data, positioning
start information
Parameter, positioning data, positioning
start information
Test operation –
Zero point return control start command
Positioning control start command
JOG operation start command
Manual pulse generator operation
enable/disable command
Operation monitor Monitor data –
D75P2 Drive unit
The D75P2 and drive unit communicate the following data via the external device
connection connector.
Direction
Communication
D75P2
Drive unit Drive unit D75P2
Control signal
Signals related to commands such as
deviation counter clear signal
Signals indicating drive unit state such as
drive unit READY signal
Pulse train Pulse train output –
D75P2 Manual pulse generator
The D75P2 and manual pulse generator communicate the following data via the
external device connection connector.
Direction
Communication
D75P2
Manual pulse generator Manual pulse generator D75P2
Pulse signal –
Manual pulse generator A-phase, manual
pulse generator B-phase
D75P2 External signal
The D75P2 and external signal communicate the following data via the external
device connection connector.
Direction
Communication
D75P2
External signal External signal D75P2
Control signal –
Signals from detector such as near-point
dog signal, upper/lower limit signal, zero
point signal
Control signals from external device such
as stop signal, external start signal,
speed/position changeover signal