14 - 27
MELSEC-
A
14 TROUBLESHOOTING
Relevant buffer memory address
remote input/output device, or remote
register
Setting range Remedy
Axis 1 Axis 2
18
19
168
169
(In standard mode)
[mm] [inch] [pulse]
-2147483648 to 2147483647
[degree] 0 to 35999999
(In stepping motor mode)
[mm] [inch] [pulse]
–134217728 to 134217727
[degree] 0 to 35999999
Change the setting to within the setting range.
Change the settings so that the lower limit value is
smaller than the upper limit value with a unit other
than “degree.”
20 170 0, 1
Change the setting to within the setting range and turn
OFF then ON the
remote station READY signal
[RX(n+7)B].
21 171 0, 1
22
23
172
173
(In standard mode)
[mm] [inch] [pulse]
1 to 32767000
[degree] 1 to 32767
(In stepping motor mode)
[mm] [inch] [pulse]
1to 2047937
[degree] 1 to 2047
24 174 1 to 500
25 175 0, 1
26 176 0, 1
27 177 0, 1
28 178 0, 1, 2
29 179
0: Manual pulse generator operation
ignored
1: Manual pulse generator connected to
axis 1 is used.
2: Manual pulse generator connected to
axis 2 is used.