DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-452DAT-LINE (Data Line)
3
Error Log Entries and Test to Clear Value
Notes:
a. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate errors (if any).
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. This error is logged when the Data Line circuit pack finds an error with the
transmit/receive circuitry of an administered Data Line on circuit pack
insertion. Perform the following procedure:
1. Issue the
busyout board PCSS
command to busyout the Data Line
circuit pack on which this port resides.
2. Issue the
reset board PCSS
command. Check the Hardware Error
Log to determine if Error Type 769 is logged again for the DAT-LINE
MO.
NOTE:
When displaying errors, set the
Active Alarms Only
field
to
n
.
Table 3-191. Data Line Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 Digital Loop Around
Test (#171)
MINOR ON test port PCSSpp sh r 2
15(a) Any Audit Update Test
(#36)
18 0 busyout port PCSSpp WARNING OFF release port PCSSpp
130 (b) None WARNING ON test port PCSSpp sh
257 Conference Circuit
Test (#7)
MINOR ON test port PCSSpp l r 2
513 NPE Crosstalk Test
(#6)
MINOR ON test port PCSSpp l r 2
769(a) Any (c) None