Maintenance Objects
3-706INADS (INADS Link)
3
logged if the test result was
Command successfully completed
and Error
Codes 10 and 11 can be logged if the test result was
Command failed
. An
error is also logged against INADS if the call to INADS finally succeeds. The
INADS software (release 3.2 or later) recognizes this special "test inads" type of
alarm and automatically opens and then closes a trouble ticket which indicates
that the reason for the trouble ticket is a command is in progress or the system
has active alarms which must be reported to INADS. The
Command
successfully completed
means the switch will start the attempt to call
INADS in two minutes (the test still runs even if Alarm Origination is disabled).
The two-minute delay allows a remote INADS technician time enough to hang up
the call and thus free up the INADS line so that the switch can call INADS back.
As error conditions are encountered, errors are logged against INADS. Error
codes 1 through 9 can be logged if the test result was
Command successfully
completed
and Error Codes 10 and 11 can be logged if the test result was
Command failed
. An error is also logged against INADS if the call to INADS
finally succeeds. The INADS software (release 3.2 or later) recognizes this
special "test inads" type of alarm and automatically opens and then closes a
trouble ticket which indicates that the reason for the trouble ticket is a
test
inads-link
command. The trouble ticket alarm contains a
TESTING INADS
LINK
description field.
After entering the command, it may take as long a nine minutes for the switch to
place the call and for INADS to respond. The Error Log should be examined (use
the category
inads
) 10 minutes after successfully entering the command to
determine if the call was successful.
Use Table 3-298
to interpret the Error Log entries.
Table 3-298. INADS Link Error Log Entries Test
Error
Code
Te s t
Result Description/ Recommendation
1 0 The call was successfully placed to INADS. No trouble found.
2 0 Informative error indicating that alarm origination was disabled at the time
of the test. The test runs even if alarm origination is disabled.
1. If Alarm Origination is desired, then enable this feature with the
Maintenance-Related System Parameters Form.
2. Repeat the test.
3 0 The INADS connection is currently in use.
1. Wait 10 minutes and retry this command.
Continued on next page