DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1059TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
3
1119 ABORT The test call was aborted due to a normal call attempt on this trunk. The
test call is performed only if the trunk is idle.
1. Either wait for the normal call to terminate normally, or force it to be
dropped by using the busyout trunk command.
1120 ABORT The ISDN Trunk-side BRI trunk is in the ISDN out-of-service/far-end state.
1. Try to change the service state via Test #256 (Service State Audit Test).
Then retry this test. However, the trunk may be in the
out-of-service/far-end state due to problems at the far-end switch.
If that is the case, no remedial action can be taken at this end.
1122 ABORT There is no test line number for the far-end switch.
1. Check the Trunk Group Administration form.
1123 ABORT There is no Feature Access Code administration for this Facility Test.
1. Check the Dial Plan and Feature Administration forms.
2012
None
2000
ABORT Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2035 ABORT The call has timed out, perhaps because of a lack of system resources.
1. Wait 1 minute and try again.
2036
2037
ABORT Internal System Error.
1. Follow the recommendation for ABORT code 2012.
2038
2039
ABORT A problem occurred while trying to read the test data.
1. Wait one minute and then try again.
2. If the test aborts again in the same manner, there is a serious internal
problem.
2040 ABORT Internal System Error.
1. Follow the recommendations for ABORT code 2012.
2041 ABORT The call has timed out, perhaps because of a lack of system resources.
1. Follow the recommendations for ABORT code 2035.
2066 ABORT Could not establish test call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2067 ABORT The call has timed out, perhaps because of a lack of system resources.
1. Follow the recommendations for ABORT code 2035.
Table 3-471. TEST #258 ISDN TEST Call — Continued
Error
Code
Te s t
Result Description/ Recommendation
Continued on next page