DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-29Logging On/Off
1
To remove the Facility Test Calls Access Code, do the following:
1. Enter
change feature-access-codes
to display the Feature Access Code
screen.
2. Leave the
Facility Test Calls Access Code
field
blank
.
!
CAUTION:
No alarms report through the INADS interface if Alarm Origination is
disabled.
!
CAUTION:
A busied out resource is one that is out of service. Be sure to verify if a
busied resource needs to be released or if the resource should remain
busied out.
Figure 1-6. Logoff Screen
To Display a Login
1. Enter the command
display login [login name]
and press Enter.
The system displays the requested login’s:
■ Name
■ Login type
■ Service level
■ Disable following a security violation value
■ Access to INADS Port value
■ Password aging cycle length
■ Facility test call notification and acknowledgment
■ Remote access notification and acknowledgment
Facility Test Call Administered
Remote Access Administered
Alarm Origination is currently disabled.
Active major or minor alarm detected; be sure to resolve it.
*** Busied out resource detected; verify if release is needed! ****
Proceed With Logoff: [n]