Maintenance Objects
3-1292XXX-BD (Common Port Circuit Pack)
3
Ringing Application Test (#51)
This test checks the ringing application circuitry common to all ports on an
Analog Line circuit pack.
EXTRA BD Certain circuit packs have limitations on how many circuit packs
can be in the system such as the Call Classifier (TN744). The Call
Classifier allow only 10 circuit packs in each system. All additional
circuit packs return EXTRA-BD and should be removed.
any NO BOARD This is normal if the test is being done when (a) the circuit pack is
not physically in the system or (b) the system is booting up.
Otherwise, there is some inconsistency between the physical
configuration and the data kept in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals for a maximum of 5
times.
Table 3-553. TEST #51 Ringing Application Circuit Test
Error
Code
Te s t
Result Description/ Recommendation
1000 or
2100
ABORT Could not allocate the necessary system resources to run test.
ABORT Could not allocate the necessary system resources to run test. The circuit
pack is not installed. Internal System Error.
2000 ABORT There was no response from the board.
1. If error type 1538 (hyperactivity) is present in the error log, follow the
maintenance strategy that is recommended for this error type.
2. Run the busyout board, reset board, and release busy board
commands,and then retest.
3. If the test still aborts, dispatch with the circuit pack.
4. Check the off-board wiring and the terminal, and, if there are no
problems found, replace the circuit pack.
Continued on next page
Table 3-552. TEST #50 NPE Audit Test — Continued
Error
Code Test Result Description/ Recommendation
Continued on next page